Influence Of Activated Carbon On Total Suspended Solids And Relative Plugging Index Of Injection Water From X-Oilfield
DOI:
https://doi.org/10.29017/SCOG.36.3.771Keywords:
Activated carbon, total suspended solids, relative plugging index.Abstract
Produced water will be used as injection water for water flooding need, but, based on the results of water quality tests show poor injection water quality caused by a lot of solids particles with high total suspended solids (TSS) concentration and high relative plugging index (RPI) obtained in the injection water. When, the condition of injection water without treatment is injected into formation will cause serious plugging. In this study, two methods used to minimize the high TSS and RPI problems are treatment with chemical and filtration (activated carbon). The use of optimal concentration of scale inhibitor in the injection water can reduce TSS and RPI in the injection water, but it does not work effectively, so that its water quality is still poor water quality and can cause plugging in the formation. Another method is filtration with activated carbon filter media which has characteristics of adsorption and large specific area to filter insoluble materials in the injection water. After filtration, the filtrate of the injection water results in clear water condition. Based on the results of laboratory tests indicate that the filtrate of the injection water contains the least solids particles with small particle size, low total suspended solids concentration and low relative plugging index value. When, it is injected into formation, the possibility of plugging occurrence can be minimized, although, there is increase of pH value, but, in general, the filtrate of the injection water can be categorized good water qualityReferences
API – RPI 45: Recommended Practice for Water
Analysis Procedure, American Petroleum Institute,
Dallas.
ASTM, Designation: D 4822 – 88 (Reapproved
: “Standard Guide for Selection of Methods of
Particle Size Analysis of Fluvial Sediments (Manual
Methods)â€.
Cowan, J.C. and Weintritt, D.J., 1976, “Water
Formed Scale Depositsâ€, Houston, Gulf Publishing
Co.
Johnson, A., King, G.S. Crabtree, M., Eslinger, D.,
Miller, P.F.M., 1999, â€Fight Scale Removed and
Preventionâ€, Oilfield Review – Schlumberger.
Jones, L.W. : 1988, “ Corrosion and Water Technology
For Petroleum Producersâ€, OGGI Publication, Tulsa.
Patton. Charles. C., 1986, “Applied Water
Technologyâ€, First Printing, June, , Oklahoma, USA, .
Richaed W.F, Bertrand W.D. and Susan L.K.,
Impoved Granular activated Carbon For The
Stabilization of Waste Water pH, Calcon Carbon Drive,
Pitsburgh, PA 15205.
Downloads
Issue
Section
License
Copyright (c) 1970 SCIENTIFIC CONTRIBUTIONS OIL AND GAS (SCOG)

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors are free to Share — copy and redistribute the material in any medium or format for any purpose, even commercially Adapt — remix, transform, and build upon the material for any purpose, even commercially.
The licensor cannot revoke these freedoms as long as you follow the license terms, under the following terms Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.